How to on and off LED Subclock populated?
Hello, Thanks for reaching out to the Volt Tech Community! However, the error occurs because the code is checking for a sub-clock, If you apply your customized board and you do not have a sub-clock connected to your board. So, yes the answer to this is to set the' Subclock Populated' value to' Not pRead more
Hello,
Thanks for reaching out to the Volt Tech Community!
However, the error occurs because the code is checking for a sub-clock, If you apply your customized board and you do not have a sub-clock connected to your board.
So, yes the answer to this is to set the’ Subclock Populated’ value to’ Not populated’.
Regards,
Ashish
See lessHow does System Reset Work on CYW43907?
Hi, HIB_REG_ON_IN is applied by the hibernation block to power up or power down the internal CYW43907 controllers. For applications that use the hibernation block, HIB_REG_ON_OUT must connect to REG_ON. Also, when de-asserted, this pin holds the WLAN and APP sections in reset. SRSTn- System reset. TRead more
Hi,
HIB_REG_ON_IN is applied by the hibernation block to power up or power down the internal CYW43907 controllers. For applications that use the hibernation block, HIB_REG_ON_OUT must connect to REG_ON. Also, when de-asserted, this pin holds the WLAN and APP sections in reset.
SRSTn- System reset. This active-low signal resets the backplanes.
Yes, After reset FW is also reloaded
Thanks,
Sachin Sharma
See lessWhat are the difference between ME and EE components?
Welcome @kamalaswal, to the community! ME = SM6T18CA (bidirectional)EE = SM6T18A (unidirectional, equal datasheet) The unidirectional TVS has a unique polarity, which is why its cathode is labeled with a dash/bar. The bi-directional one is electrically symmetrical and can be installed with any polarRead more
Welcome kamalaswal, to the community!
ME = SM6T18CA (bidirectional)
EE = SM6T18A (unidirectional, equal datasheet)
The unidirectional TVS has a unique polarity, which is why its cathode is labeled with a dash/bar. The bi-directional one is electrically symmetrical and can be installed with any polarity.
Hope that helps.
Regards
Alex Thomas
See lessHow to use WROVER and LAN8720A together in a design?
Hello, I did this numerous years ago, so I'm still determining what has been modified in the software. But back also you could configure to use GPIO0 as the CLK.The problem with this was that it didn't allow uploading the firmware automatically. You had to manually keep GPIO0 low and reset it to putRead more
Hello,
I did this numerous years ago, so I’m still determining what has been modified in the software. But back also you could configure to use GPIO0 as the CLK.
The problem with this was that it didn’t allow uploading the firmware automatically. You had to manually keep GPIO0 low and reset it to put it in bootloader mode for downloading. I wouldn’t say I liked this approach so I did it this way rather.
I do not use that design presently, mostly because I only use the ESP32- S3, and there’s no stock of the LAN8720A. When I need Ethernet I use the KSZ8851SNL Ethernet Controller. Works great.
Thank You
See lessUnexpected ADC Behavior Open Channels Displaying ANxx0 Data in nonstop Scan Mode
Hello, Thanks for reaching out to the Volt Tech Community. This action isn't unexpected it's quite normal. Because there's alone one sample and hold circuit, in nonstop scan mode if one channel is floating, the voltage of the next channel will still be present on the capacitor of the sample and holdRead more
Hello,
Thanks for reaching out to the Volt Tech Community.
This action isn’t unexpected it’s quite normal.
Because there’s alone one sample and hold circuit, in nonstop scan mode if one channel is floating, the voltage of the next channel will still be present on the capacitor of the sample and hold circuit.
In general, it isn’t recommended to leave analog pins floating as their results are invalid.
However, if you leave them open you can use the A/D Disposition Discovery Control Register. With this functionality, between the conversion of each channel, the capacitor of each channel will be discharged and near 0.
The further states for discharge, the further discharge will be.
I hope it helps.
Regards
Jullian White
See lessHow to use Low voltage Ballast ICs for UV- C Disinfection Lamps?
Hi @Swiftconnect, The ICB2FL03G's turn-on threshold is 14.0 volts, still, the input voltage needed for your application is 12 volts. Therefore, ICB2FL03G will not be the best option for your application. We do not presently have any other dedicated controller for UV-C disinfection lamps except for tRead more
Hi Swiftconnect,
The ICB2FL03G’s turn-on threshold is 14.0 volts, still, the input voltage needed for your application is 12 volts. Therefore, ICB2FL03G will not be the best option for your application. We do not presently have any other dedicated controller for UV-C disinfection lamps except for the ICB2FL03G.
Regards,
See lessNidhi Singh
Can HRTIM FAULT function software triggered and reset periodicly?
Hello @Erica First, let me thank you for posting. 1- To achieve a cycle-by-cycle protection function, you would need to apply your own logic using the HRTIM's capture compare features and interrupts. You could set up a capture compare unit to sample a specific signal or condition on each cycle and aRead more
Hello Erica Mills
First, let me thank you for posting.
1- To achieve a cycle-by-cycle protection function, you would need to apply your own logic using the HRTIM’s capture compare features and interrupts.
You could set up a capture compare unit to sample a specific signal or condition on each cycle and also use an interrupt to perform the necessary actions or trigger a fault if the condition exceeds a certain threshold.
This approach would require careful configuration and software implementation to achieve the required functionality.
2- Regarding the HRTIM initialization in CubeMX, the default configuration may indeed enable blanking.
Blanking is a point that prevents certain events (similar to fault events) from occurring immediately after a compare match. It provides a delay to avoid false triggering caused by transient effects.
While blanking can be useful in some applications, it might not be necessary or appropriate for all cases.
However,
If you believe that blanking is causing misunderstanding or unwanted behavior in your application.
you can modify the HRTIM configuration in CubeMX to disable or adjust the blanking settings according to your conditions. By customizing the initialization code, you can ensure that the HRTIM operates as desired in your specific use case.
Best Regards
Vikas Nagpal
See lessHow to find the API for CAN Bus Filtering RA4M1?
Hello, Thanks for reaching out to Volt Tech Community. The acceptance filter of CAN is implemented with 8 acceptance masks (one mask for every four mailboxes). Masks are independently enabled or disabled for each mailbox. This cannot be done with FSP APIs. You can either manually write the Mask RegiRead more
Hello,
Thanks for reaching out to Volt Tech Community.
The acceptance filter of CAN is implemented with 8 acceptance masks (one mask for every four mailboxes). Masks are independently enabled or disabled for each mailbox. This cannot be done with FSP APIs. You can either manually write the Mask Registers (MKRk) (k = 0 to 7) or more easily set the group masks on the FSP configurator:
The above settings will set the MKR registers automatically:
Regards
Ashish
See lessHow to Get Dimmable LED Driver with True Constant Output Current?
Hi @Farmanali, Infineon has a pervasive and wide range of portfolios for LED drivers. We've best-in-class technologies that can be used in various LED lighting applications. Yes, We have a wide range of products in our portfolio that can support dimmable constant current output you can Please relateRead more
Hi farmanali,
Infineon has a pervasive and wide range of portfolios for LED drivers. We’ve best-in-class technologies that can be used in various LED lighting applications.
Yes, We have a wide range of products in our portfolio that can support dimmable constant current output you can Please relate to the product webpage for further details.
The various subcategories for LED drivers in our portfolio are as follows-
1. DC LED Driver IC
2. DC LED Driver IC
3. LED Dimming Interface IC
4. Linear LED Driver IC
5. Ballast IC
6. NFC- PWM configuration IC
7. LITIX ™- Automotive LED Driver IC
Best Regards,
Sachin Sharma
See lessHow to Get High Speed LED Driver in Different Series?
Hello, Right, existing LED drivers all have PWM engines. It depends on the LED, some have Vf = 1.8, and some have 3.5V. So, 15x3.5 = 52.5 V in direct mode. Also current, 20 mA or more? For low current low voltage OPA may be an option, or OPA buffered by transistor for high CV. Thank You
Hello,
Right, existing LED drivers all have PWM engines.
It depends on the LED, some have Vf = 1.8, and some have 3.5V. So, 15×3.5 = 52.5 V in direct mode. Also current, 20 mA or more?
For low current low voltage OPA may be an option, or OPA buffered by transistor for high CV.
Thank You