Is a LDO in bypass mode still controllable by the sequencer of the DA9063? Is it also possible to enable and disable LDOs in bypass mode?
Pls check for boot jumper refer below link to download E2 lite manual for connection reference https://www.renesas.com/in/en/document/mat/e2-emulator-e2-emulator-lite-additional-document-users-manual-notes-connection-ra-devices
Pls check for boot jumper
refer below link to download E2 lite manual for connection reference
See less
Yes, LDOs 3,4,7,8 and 11 can be set to bypass mode by setting LDO<x>_BYP register to (1) and by setting LDO<x>_AUTO to (1). In sequencing they follow LDO<x> _STEP timing. Please note: Voltage monitoring function cannot be used for any LDO in bypass mode.
Yes, LDOs 3,4,7,8 and 11 can be set to bypass mode by setting LDO<x>_BYP register to (1) and by setting LDO<x>_AUTO to (1). In sequencing they follow LDO<x> _STEP timing.
Please note: Voltage monitoring function cannot be used for any LDO in bypass mode.