How many cells in total can be linked at most in ISL94212 and does it support 125 degrees in terms of operational temperature range?
We used following in monitoring procedure on life tests Junction temperature of the devices under stress (Tj stress) 125 °C Average temperature in the user/application environment (Tj user) 55 °C, Burning test , in this device there is some extra feature like OTP, HV cutt-off, and it is final testedRead more
We used following in monitoring procedure on life tests
Junction temperature of the devices under stress (Tj stress) 125 °C
Average temperature in the user/application environment (Tj user) 55 °C, Burning test , in this device there is some extra feature like OTP, HV cutt-off, and it is final tested part for MP ,
Thanks
See less
Hi, Yes, it will support voltage monitors for up to 12 cells, as well as Li-Ion CoO2, Li-Ion Mn2O4, and Li-Ion FePO4 chemistries. The ISL94212 is available in a 64 Ld TQFP package and has a -40°C to +85°C operational temperature range specification. It does not support 125°. Thanks
Hi,
Yes, it will support voltage monitors for up to 12 cells, as well as Li-Ion CoO2, Li-Ion Mn2O4, and Li-Ion FePO4 chemistries. The ISL94212 is available in a 64 Ld TQFP package and has a -40°C to +85°C operational temperature range specification. It does not support 125°.
Thanks
See less