X28HC64 ,64K,8BIT EPROM
Hi Baba, This device is used single 5 volt supply and supply voltage Range will be (4.5volt-5.5Volt) for you more detail please see below attached fig.
Hi Baba,
This device is used single 5 volt supply and supply voltage Range will be (4.5volt-5.5Volt) for you more detail please see below attached fig.
See lessAn OpAm’s maximum output current
Hi Saif, Most datasheets have figures where you can get this information.if you not get any datasheet then you can find this data in graph ,It displays the output voltage versus output current. Thanks
Hi Saif,
Most datasheets have figures where you can get this information.if you not get any datasheet then you can find this data in graph ,It displays the output voltage versus output current.
Thanks
See lessISL94212
Hi, Yes, it will support voltage monitors for up to 12 cells, as well as Li-Ion CoO2, Li-Ion Mn2O4, and Li-Ion FePO4 chemistries. The ISL94212 is available in a 64 Ld TQFP package and has a -40°C to +85°C operational temperature range specification. It does not support 125°. Thanks
Hi,
Yes, it will support voltage monitors for up to 12 cells, as well as Li-Ion CoO2, Li-Ion Mn2O4, and Li-Ion FePO4 chemistries. The ISL94212 is available in a 64 Ld TQFP package and has a -40°C to +85°C operational temperature range specification. It does not support 125°.
Thanks
See lessReliability data in Renesas RAA223011
We used following in monitoring procedure on life tests Junction temperature of the devices under stress (Tj stress) 125 °C Average temperature in the user/application environment (Tj user) 55 °C, Burning test , in this device there is some extra feature like OTP, HV cutt-off, and it is final testedRead more
We used following in monitoring procedure on life tests
Junction temperature of the devices under stress (Tj stress) 125 °C
Average temperature in the user/application environment (Tj user) 55 °C, Burning test , in this device there is some extra feature like OTP, HV cutt-off, and it is final tested part for MP ,
Thanks
See lessemergency inverter light
You can use this device for either solution, regardless of your application, so yes. Thanks
You can use this device for either solution, regardless of your application, so yes.
Thanks
See lessDriver on board
Hi , Since this is a three channel gadget, the first channel must be powered by a minimum of 108 volts, so I advise using 12 LEDs for 3 watt . Thanks
Hi ,
Since this is a three channel gadget, the first channel must be powered by a minimum of 108 volts, so I advise using 12 LEDs for 3 watt .
Thanks
Driver on board
Dear Sir, you can go with Single channel DOB IC BP5151DK , for more information we will discuss on email Thanks
Dear Sir,
you can go with Single channel DOB IC BP5151DK , for more information we will discuss on email
Thanks
See lessISL94212
Hi dear, A scan counter is provided to allow confirmation of receipt of the Scan and Measure commands. This is a 4-bit counter located in the Scan Count register (page 1, address 6’h16). The counter increments each time a Scan or Measure command is received. This allows the host microcontrollRead more
Hi dear,
A scan counter is provided to allow confirmation of receipt of the Scan and Measure commands. This is a 4-bit counter located in the Scan Count register (page 1, address 6’h16). The counter increments each time a Scan or Measure command is received. This allows the host microcontroller to compare the counter value before and after the Scan or Measure command was sent to verify receipt. The counter wraps to zero when overflowed. The scan counter increments whenever the ISL94212 receives a Scan or Measure command. The ISL94212 does not perform a requested scan or measure function if there is already a scan or measure function in progress, but it still increments the scan counter.
Thanks
Non-volatile Memory
Hi , A checksum is provided to verify the contents of EEPROM memory. Two registers are provided. One contains the correct checksum value, which is calculated during factory testing at Intersil. The other contains the checksum value that is calculated each time the non-volatile memory is loadeRead more
Hi ,
A checksum is provided to verify the contents of EEPROM memory. Two registers are provided. One contains the correct checksum value, which is calculated during factory testing at Intersil. The other contains the checksum value that is calculated each time the non-volatile memory is loaded to shadow registers,
Thanks
Sandeep
See lessDatasheet of iW1822-00
Hi, Yes, you can use it for a 3-phase metre, and please refer to the accompanying schematic .
Hi,
Yes, you can use it for a 3-phase metre, and please refer to the accompanying schematic .
See less