ESP32-C3 MINI-1 Module Programming?
Hello, I just spent quite a bit of time figuring out why I could not upload to my own boards, so I appreciate what you are experiencing. The ESP32- C3- Mini modules don't need to be preprogrammed. You can write firmware to them directly using esptool.py I programmed mine using the Arduino IDE, whichRead more
Hello,
I just spent quite a bit of time figuring out why I could not upload to my own boards, so I appreciate what you are experiencing.
The ESP32- C3- Mini modules don’t need to be preprogrammed. You can write firmware to them directly using esptool.py
I programmed mine using the Arduino IDE, which uses esptooly.py under the hood.
Still, we might be suitable to help, If you share what your custom programming board looks like.
Thank You & Regards
Nidhi
See lessESP32 Box Arrived But Not Responding?
Hello, However, you can try to disassemble it, If you're willing to try to fix it yourself. The microphones are on a separate board that's connected to the main board with a 6- pin FPC cable; it would probably be a good idea to check if that's still inserted and snug. Thanks
Hello,
However, you can try to disassemble it, If you’re willing to try to fix it yourself. The microphones are on a separate board that’s connected to the main board with a 6- pin FPC cable; it would probably be a good idea to check if that’s still inserted and snug.
Thanks
See lessMISO Generate Pointless Pulse?
Hi, The MISO pulses manifest at some stage in SPI idle state (while the clock is idle among the transfers). In master mode (in SPI, now no longer SCI_SPI) there's the choice to pick out MOSI idle level at low or high based on the MOIFE and MOIFV bit settings in SPPCR. However, there's no such choiceRead more
Hi,
The MISO pulses manifest at some stage in SPI idle state (while the clock is idle among the transfers).
In master mode (in SPI, now no longer SCI_SPI) there’s the choice to pick out MOSI idle level at low or high based on the MOIFE and MOIFV bit settings in SPPCR.
However, there’s no such choice in slave mode to choose the idle level of MISO.
We could help greater in case you share more information about why those pulses are trouble to your application.
Regards,
Nidhi
See lessUsing SWD Pins as General- Purpose Outputs on XMC1202?
Hi, SWD pins may be used as general-purpose IOs, but this change has to be done only after you program your device. Are you following this flow? You may use the XMC_GPIO_Init () API to initialize the SWD pin as GPIO. It should be noted that debug functionality can not be used when SWD lines are confRead more
Hi,
SWD pins may be used as general-purpose IOs, but this change has to be done only after you program your device. Are you following this flow? You may use the XMC_GPIO_Init () API to initialize the SWD pin as GPIO.
It should be noted that debug functionality can not be used when SWD lines are configured as GPIOs.
Regards,
See lessESP32 Wrover Resets Upon Contactor Shutdown (Noise)?
Hello, Likely either EMC or a power force dip. Make sure the power supply of the ESP is well-isolated from the contactor coil. Thanks & Regards Nidhi Singh
Hello, Likely either EMC or a power force dip. Make sure the power supply of the ESP is well-isolated from the contactor coil.
Thanks & Regards
Nidhi Singh
See lessHow to Change Device Part Number in Modus Toolbox XMC?
Hello, You can click the "Reset" button and then have a try. Regards, Nidhi Singh
Hello, You can click the “Reset” button and then have a try.
Regards,
Nidhi Singh
See lessWhy BLESS library missing in MTB3.0?
Hello, In MTB, the new AIROC BT Stack will be supported. The legacy stack will be shut off, and this stack will be supported only with PSoC Creator. In MTB 3.0, BLESS library is removed from the library manager. You have to use the new AIROC BT Stack. Thanks, Nidhi Singh.
Hello,
In MTB, the new AIROC BT Stack will be supported. The legacy stack will be shut off, and this stack will be supported only with PSoC Creator.
In MTB 3.0, BLESS library is removed from the library manager. You have to use the new AIROC BT Stack.
Thanks,
See lessNidhi Singh.
Why USB PCDC Stack Shows an Error?
Hello, You need to go to the" Clocks" tab of the FSP configurator and enable the UCLK clock. also, adjust your PLL Mul and UCLK Div to reach the UCLK frequency of 48 MHz. Kind regards,
Hello,
You need to go to the” Clocks” tab of the FSP configurator and enable the UCLK clock. also, adjust your PLL Mul and UCLK Div to reach the UCLK frequency of 48 MHz.
See lessKind regards,
How to Save Data After Power Off with RA6T1?
Hi, Thanks for reaching out to Volt.Tech Engineering Community. As stated in 41.15.5 of the flash section, the operating voltage range (VCC2.7 to3.6 V for RA6T1) should be within the allowed range. Let us know if it helps.
Hi,
Thanks for reaching out to Volt.Tech Engineering Community.
As stated in 41.15.5 of the flash section, the operating voltage range (VCC2.7 to3.6 V for RA6T1) should be within the allowed range.
See lessLet us know if it helps.
Is it possible to read the battery percentage of the device connected by USB- C?
Hello, Battery_status message can give the SOC of the sink. The info will be available only on the PD3 sink( designed with version> = PD3.0 v1.2). PD2 devices do not have similar communication. That information is handled in the dpm_user part and needs to be updated by the user/ customer. Best reRead more
Hello,
Battery_status message can give the SOC of the sink.
The info will be available only on the PD3 sink( designed with version> = PD3.0 v1.2).
PD2 devices do not have similar communication.
That information is handled in the dpm_user part and needs to be updated by the user/ customer.
Best regards
See less